Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.787
Filtrar
1.
Kardiologiia ; 64(3): 40-45, 2024 Mar 31.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-38597761

RESUMO

AIM: Comparative analysis of the height of atherosclerotic plaques (AP) in the descending thoracic aorta (TA) according to two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), and contrast-enhanced multislice computed tomography (MSCT). MATERIAL AND METHODS: The TA was examined using 2D, 3D TEE and contrast-enhanced MSCT in 34 patients (20 men and 14 women aged 68 [62; 71] years). AP heights were compared using the Bland-Altman method and the Spearman correlation analysis. This was a blinded comparative study which assessed the AP morphometry using each of the radiation modalities without knowing the results of the method being compared. RESULTS: 100 APs were examined in the descending TA. The mean height of all analyzed APs in the descending TA was 2.2 mm [2; 2.7] for 2D TEE, 3.1 mm [2.7; 3.55] for 3D TEE, and 3.05 mm [2.55; 3.55] for MSCT. The AP heights measured with 2D TEE was statistically significantly smaller than the heights of similar APs measured either with 3D TEE or MSCT. The mean difference (bias) was 0.88±0.34 mm between 2D and 3D TEE, and 0.83±0.41 mm between 2D TEE and MSCT. The correlation coefficients for the AP heights were r=0.87 (p<0.001) between 2D and 3D TEE and r=0.86 (p<0.001) between 2D TEE and MSCT. There were no differences in the height of similar APs between 3D TEE and MSCT. CONCLUSION: The three-dimensional reconstruction of AP in the TA by TEE is more accurate for quantitative assessment of AP than a two-dimensional study.


Assuntos
Ecocardiografia Tridimensional , Placa Aterosclerótica , Masculino , Humanos , Feminino , Aorta Torácica/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Transesofagiana
2.
Ann Card Anaesth ; 27(2): 159-161, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38607880

RESUMO

ABSTRACT: The elephant trunk procedure, an endovascular strategy for retrograde type A acute aortic dissection, is associated with several complications, hemolytic anemia being a rare one. We performed endovascular stent-graft insertion in a patient who developed hemolytic anemia. Transesophageal echocardiography (TEE) detected turbulent jet flow and stenosis position, which was not detected by angiography and intravascular ultrasound (IVUS). This imaging technique proved effective for malperfusion diagnosis and enabled us to confirm its resolution after the endovascular procedure. Intraoperative TEE is a useful adjunct to angiography and IVUS for diagnosis and therapeutic assessment during endovascular repair of a stenosed elephant trunk.


Assuntos
Anemia Hemolítica , Dissecção Aórtica , Humanos , Ecocardiografia Transesofagiana , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Ecocardiografia , Angiografia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Constrição Patológica
3.
Tex Heart Inst J ; 51(1)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38623730

RESUMO

Chylothorax after cardiac surgery is a rare complication associated with severe morbidity and mortality. This report documents successful treatment with percutaneous thoracic duct embolization for chylothorax after total arch replacement. A 69-year-old man underwent replacement of the aortic arch to treat a ruptured aortic aneurysm. After surgery, the left thoracic drain discharged 2,000 to 3,000 mL serosanguineous fluid per day, even though the patient took nothing orally and was administered subcutaneous octreotide therapy. On postoperative day 9, percutaneous thoracic duct embolization was performed, and the drain could be removed. The chylothorax did not recur, and the patient was discharged on postoperative day 17.


Assuntos
Quilotórax , Embolização Terapêutica , Masculino , Humanos , Idoso , Quilotórax/diagnóstico por imagem , Quilotórax/etiologia , Ducto Torácico/cirurgia , Complicações Pós-Operatórias , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia
5.
Rev Med Liege ; 79(4): 199-201, 2024 Apr.
Artigo em Francês | MEDLINE | ID: mdl-38602205

RESUMO

We report the case of a 36-year-old female whose dysphagia revealed a congenital anomaly of the thoracic aorta: the right aortic arch with mirror image branching. This is a rare embryonic developmental anomaly where the aorta wraps around the right bronchus and the supra-aortic trunks emerge from the arch in the opposite order to normal. Most of the patients are asymptomatic unless there is a significant compression of mediastinal structures. Major compression of the esophagus or trachea, aneurysmal disease, dissection of the thoracic aorta, or the presence of a Kommerell diverticulum larger than 2 cm may require a surgical repair. There is no standard treatment and it must be adapted to the clinical presentation and the anatomic configuration of each patient. Our patient did not receive any treatment for her condition.


Nous rapportons le cas d'une patiente de 36 ans dont le tableau de dysphagie a permis de mettre en évidence une anomalie congénitale de l'aorte thoracique : l'arc aortique droit avec image en miroir. Il s'agit d'une anomalie de développement embryonnaire rare où l'aorte s'enroule autour de la bronche souche droite et où les troncs supra-aortiques émergent de la crosse dans l'ordre inverse et opposé à la normale. La grande majorité des patients est asymptomatique, à moins qu'il existe une compression des structures médiastinales. Une compression majeure de l'oesophage ou de la trachée, une maladie anévrismale, une dissection de l'aorte thoracique ou la présence d'un diverticule de Kommerell de plus de 2 cm peuvent justifier une sanction chirurgicale. Il n'y a pas de traitement standard et celui-ci doit être adapté à la présentation clinique et à la configuration anatomique du patient. Notre patiente n'a bénéficié d'aucun traitement pour son affection.


Assuntos
Aorta Torácica , Transtornos de Deglutição , Feminino , Humanos , Adulto , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/anormalidades , Aorta Torácica/cirurgia , Transtornos de Deglutição/etiologia , Mediastino , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/anormalidades , Artéria Subclávia/cirurgia
7.
Magn Reson Imaging ; 109: 67-73, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38484947

RESUMO

PURPOSE: To investigate longitudinal thoracic aorta injury using 3-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) parameters and to evaluate their value for predicting the subsequent main adverse cardiovascular events (MACEs) in breast cancer patients receiving anthracyclines. METHODS: Between July 2020 and July 2021, eighty-eight female participants with breast cancer scheduled to receive anthracyclines with or without trastuzumab prospectively enrolled. Each subjects underwent 4D flow MRI at baseline, 3 and 6 months in relation to baseline. The diameter, peak velocity (Vpeak), wall shear stress (WSS), pulse wave velocity (PWV), energy loss (EL) and pressure gradient (PG) of thoracic aorta were measured. The association between these parameters and subsequent MACEs was performed by Cox proportional hazard models. RESULTS: Ten participants had subsequently MACEs. The Vpeak and PG gradually decreased and the WSS, PWV and EL progressively increased at 3 and 6 months compared with baseline. Adjusted multivariable analysis showed that the WSS of the proximal, mid- and distal ascending aorta [HR, 1.314 (95% confidence interval (CI): 1.003, 1.898)], [HR, 1.320 (95% CI: 1.002, 1.801)] and [HR, 1.322 (95% CI: 1.001, 1.805)] and PWV of ascending aorta [HR, 2.223 (95% CI: 1.010, 4.653)] at 3 months were associated with subsequent MACEs. Combined WSS and PWV of ascending aorta at 3 months yielded the highest AUC (0.912) for predicting subsequent MACEs. CONCLUSION: Combined WSS and PWV of ascending aorta at 3 months is helpful for predicting the subsequent MACEs in breast cancer patients treated by anthracyclines.


Assuntos
Neoplasias da Mama , Doenças Cardiovasculares , Humanos , Feminino , Aorta Torácica/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Análise de Onda de Pulso , Antraciclinas/efeitos adversos , Estudos Longitudinais , Imageamento por Ressonância Magnética/métodos , Doenças Cardiovasculares/patologia , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Estresse Mecânico
8.
BMJ Case Rep ; 17(3)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38521516

RESUMO

A patient in his late 30s presented with issues of retrosternal chest pain and palpitations. He had sustained a splinter injury to the left hemithorax a year ago for which he had been managed with a tube thoracostomy. During subsequent evaluations, he was found to have atrial fibrillations and a CT angiography revealed an arch of the aorta pseudoaneurysm with a fistulous communication with the innominate vein, which being a rare condition has no established treatment protocols. Endovascular salvage of the condition required an aortic Ishimaru zone 2 deployment of the thoracic endovascular aortic repair stent graft to provide an adequate landing zone. The elective left subclavian artery revascularisation was obtained by a left carotid artery to left subclavian artery bypass. Post procedure there was complete exclusion of the pseudoaneurysm sac, and the fistulous aorto-venous communication inflow tract. The patient recuperated well and has returned to full active duties.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Traumatismos Torácicos , Humanos , Masculino , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/lesões , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Veias Braquiocefálicas/diagnóstico por imagem , Veias Braquiocefálicas/cirurgia , Desenho de Prótese , Stents , Traumatismos Torácicos/cirurgia , Resultado do Tratamento , Adulto
9.
Am J Cardiol ; 218: 86-93, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38452843

RESUMO

Findings regarding the relation between aortic size and risk factors are heterogeneous. This study aimed to generate new insights from a population-based adult cohort on aortic root dimensions and their association with age, anthropometric measures, and cardiac risk factors and evaluate the incidence of acute aortic events. Participants from the fifth examination round of the Copenhagen City Heart study (aged 20 to 98 years) with applicable echocardiograms and no history of aortic disease or valve surgery were included. Aorta diameter was assessed at the annulus, sinus of Valsalva, sinotubular junction, and the tubular part of the ascending aorta. The study population comprised 1,796 men and 2,316 women; mean age: 56.4 ± 17.0 and 56.9 ± 18.1 years, respectively. Men had larger aortic root diameters than women regardless of height indexing (p <0.01). Age, height, weight, systolic and diastolic blood pressure, mean arterial pressure, pulse pressure, hypertension, diabetes, ischemic heart disease, and smoking were positively correlated with aortic sinus diameter in the crude and gender-adjusted analyses. However, after full adjustment, only height, weight, and diastolic blood pressure remained significantly positively correlated with aortic sinus diameter (p <0.001). For systolic blood pressure and pulse pressure, the correlation was inverse (p <0.001). During follow-up (median 5.4 [quartile 1 to quartile 3 4.5 to 6.3] years), the incidence rate of first-time acute aortic events was 13.6 (confidence interval 4.4 to 42.2) per 100,000 person-years. In conclusion, beyond anthropometric measures, age, and gender, diastolic blood pressure was the only cardiac risk factor that was independently correlated with aortic root dimensions. The number of aortic events during follow-up was low.


Assuntos
Hipertensão , Seio Aórtico , Adulto , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta/diagnóstico por imagem , Ecocardiografia , Seio Aórtico/diagnóstico por imagem
10.
Surg Radiol Anat ; 46(4): 519-522, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38480591

RESUMO

PURPOSE: A right aortic arch (RAA) is a rare vascular anomaly that often coexists with an aberrant left subclavian artery (ALSA). Due to the rarity of RAA, the development of an ALSA is not well understood. METHOD: We describe a case in which a 58-year-old man who was scheduled to undergo posterior decompression and fusion surgery for thoracic ossification of the posterior longitudinal ligament from Th1 to Th3 was found to have a RAA and an ALSA. RESULTS: Preoperative computed tomography angiography demonstrated a RAA and an ALSA. The ALSA was extremely tortuous and ran in the paraspinal muscles behind the thoracic laminae, which meant it was in the surgical field. The ALSA arose from the descending aorta and bifurcated into the left segmental arteries of Th1 and Th2, and also bifurcated into the left vertebral artery, which had a normal subsequent course. The dysplastic ALSA was considered to have developed from the thoracic intersegmental artery. Based on preoperative examination findings, we performed spinal surgery without vessel injury. CONCLUSION: We report a rare case of a dysplastic ALSA that developed from the thoracic intersegmental artery with a RAA. The knowledge of this anomaly provides safety in spinal surgery of the cervicothoracic junction.


Assuntos
Anormalidades Cardiovasculares , Artéria Subclávia/anormalidades , Malformações Vasculares , Masculino , Humanos , Pessoa de Meia-Idade , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/anormalidades , Anormalidades Cardiovasculares/diagnóstico por imagem , Anormalidades Cardiovasculares/cirurgia , Anormalidades Cardiovasculares/complicações , Artéria Subclávia/diagnóstico por imagem , Malformações Vasculares/complicações
11.
Echocardiography ; 41(3): e15799, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38516862

RESUMO

Atherosclerosis is the most common cause of heart disease and stroke. Plaque thickness ≥4 mm in the ascending aorta or aortic arch is strongly correlated with cerebral embolic events and ischemic stroke. However, despite imaging workup, the cause of embolic stroke remains unidentified in many patients. Transesophageal echocardiography (TEE) is the preferred echocardiographic method for the evaluation of cardiac source of emboli. 2D TEE imaging evaluates aortic root and aortic arch in a single plane or two planes with biplane imaging. However, 2D TEE often fails to detect mobile or complex components in the ascending aorta and aortic arch plaques. The routine availability of 3D TEE in current ultrasound systems may significantly improve the assessment of aortic plaques as a potential embolic source. In this case series, we present four consecutive patients with stroke who underwent TEE by a single cardiologist for possible cardioembolic source. Some of these patients may have been labelled as "cryptogenic stroke" or "embolic stroke of undetermined source" (ESUS) due to the presence of insignificant or nonmobile ascending aortic or aortic arch plaques on 2D TEE imaging. In our four consecutive patients with ESUS who underwent TEE by a single operator, 3D TEE showed complex aortic arch plaques with ulceration with mobile components and established these plaques as the likely source of embolic stroke.


Assuntos
Doenças da Aorta , Aterosclerose , AVC Embólico , Embolia , Placa Aterosclerótica , Acidente Vascular Cerebral , Humanos , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , AVC Embólico/complicações , Aterosclerose/complicações , Aterosclerose/diagnóstico por imagem , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Embolia/complicações , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem
12.
Am J Case Rep ; 25: e942974, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38526305

RESUMO

BACKGROUND The VACTEREL association is an acronym that includes vertebral malformations (V), anal atresia (A), cardiac defects (C), tracheoesophageal fistula (TE), renal defects (R), and limb malformations (L). The aortic arch is the section between the ascending aorta and the descending aorta, where some variants have been described, such as the right aortic arch and bovine aortic arch, among others. A rare presentation in the Natsis classification is the "type X" where a bovine aortic arch and anomalous origin of the left vertebral artery are present. Several structural cardiac malformations have been described in the VACTEREL association. Still, there is no bovine arch or an anomalous left vertebral artery. CASE REPORT Our patient was a 3-year-old boy with a diagnosis of VACTEREL association (type III esophageal atresia, congenital hip dislocation, scoliosis, bilateral clubfoot, and grade IV biliary ureteral reflux). Echocardiographic findings showed changes in the aortic arch, and angiotomography and magnetic resonance angiography showed a bovine aortic arch and an anomalous left vertebral artery. At the time of diagnosis, there were no clinical manifestations or complications due to the anomalous origin of the left vertebral artery. CONCLUSIONS This is the first description of a bovine type X arch according to the Natsis classification in a VACTEREL association. In general, knowledge of the anatomical variants of the aortic arch and the origin and course of the vertebral arteries is of great clinical and interventional importance, mainly because of the risk of cerebral ischemia.


Assuntos
Canal Anal/anormalidades , Aorta Torácica , Esôfago/anormalidades , Cardiopatias Congênitas , Rim/anormalidades , Deformidades Congênitas dos Membros , Coluna Vertebral/anormalidades , Traqueia/anormalidades , Masculino , Humanos , Pré-Escolar , Aorta Torácica/diagnóstico por imagem , Artéria Vertebral , Aorta , Deformidades Congênitas dos Membros/diagnóstico por imagem
13.
J Cardiothorac Surg ; 19(1): 152, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521956

RESUMO

BACKGROUND: The presence of the severe thoracic aortic calcification (TAC) in cardiac surgery patients is associated with adverse post-operative outcome. However, the relationship between cardiovascular risk factors and aortic plaque burden remains unknown. The objective of this study was to determine the predictive factors of TAC in patients candidate for cardiac surgery. METHODS: Patients who underwent thoracic CT scan prior to cardiac surgery between August 2020 to April 2021 were included. Of 556 patients, 209 (36.7%) had a thoracic aortic calcium score (TACS) ≥ 400 mm [3] and were compare with the remaining patients. Predictors of severe TAC were assessed through stepwise multivariable logistic regression analysis. RESULTS: The patients with TACS ≥ 400 had a higher mean age (67.3 ± 7.1 vs. 55.7 ± 10.6; p < 0.001) with a higher frequency of diabetes mellitus (40.7% vs. 30.8%; p = 0.018), dyslipidemia (49.8% vs. 38.6%; p = 0.010), hypertension (60.8% vs. 44.7%; p < 0.001), opium addiction (18.2% vs. 11.2%; p = 0.023), peripheral vascular disease (PVD) (7.7% vs. 2.3%; p = 0.005) as compared with TACS < 400. The multiple determinants of TAC were PVD (OR = 2.86) followed by opium addiction, diabetes and age. CONCLUSIONS: Thoracic CT scan prior to cardiac surgery for patients with older age, diabetes, opium addiction and PVD is recommended. Our study could serve as a foundation for future research endeavors aimed at establishing a risk score for TAC.


Assuntos
Doenças da Aorta , Procedimentos Cirúrgicos Cardíacos , Diabetes Mellitus , Dependência de Ópio , Humanos , Dependência de Ópio/complicações , Fatores de Risco , Tomografia Computadorizada por Raios X , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Doenças da Aorta/complicações
14.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38485695

RESUMO

Endovascular aortic arch repair (Ar-TEVAR) with single-branch, off-the-shelf Nexus aortic arch system has shown promising early and 3-year outcomes. There is lack of data regarding long-term results of this specific device, particularly regarding patency of supra-aortic bypasses and stability of the connection between the 2 modules. This case report describes 6-year clinical and imaging follow-up of a 74-year-old patient who underwent Ar-TEVAR with Nexus. Over 6 years, the patient experienced minor complications unrelated to the device. The patency of supra-aortic bypasses and integrity of the device's connection were confirmed. Computed tomography angiography constantly showed exclusion of the aneurysm and reduction of the aneurysmal sac. In conclusion, although extended research and broader data are needed, this case provides encouraging evidence of long-term results of Ar-TEVAR with Nexus.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Idoso , Prótese Vascular , Angiografia por Tomografia Computadorizada , Implante de Prótese Vascular/métodos , Stents , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Seguimentos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Estudos Retrospectivos
16.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459863

RESUMO

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Estudos Retrospectivos
17.
World Neurosurg ; 184: e633-e646, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38342167

RESUMO

OBJECTIVE: To investigate the association between intracranial aneurysms (IAs) and thoracic aortic diameter. METHODS: This observational cohort study examined thoracic aortic diameters in patients with IA. Patients were categorized by IA size (<7 mm and ≥7 mm) and IA status (ruptured/unruptured) based on radiologic findings. We investigated the association between thoracic aortic diameter and IA size and status using binary and linear regression as univariate and multivariable analyses. RESULTS: A total of 409 patients were included. Mean age was 60 (±11.7) years and 63% were women. Thoracic aortic diameters were greater among patients who had an IA ≥7 mm versus IA <7 mm (P < 0.05). In the univariate analysis, the diameter of the ascending aorta (odds ratio [OR], 1.07; 95% confidence interval [CI], 1.02-1.129 per 1 mm; P = 0.002), aortic arch (OR, 1.10; 95% CI, 1.04-1.15 per 1 mm; P < 0.001), and descending aorta (OR, 1.10; 95% CI, 1.03-1.16 per 1 mm; P = 0.003) were associated with IAs ≥7 mm. In the multivariable regression model, larger ascending aorta (OR, 1.09; 95% CI, 1.01-1.17 per 1 mm; P = 0.018), aortic arch (OR, 1.12; 95% CI, 1.02-1.22 per 1 mm; P = 0.013), and descending aorta (OR, 1.20; 95% CI, 1.08-1.33 per 1 mm; P < 0.001) were associated with ruptured IA. CONCLUSIONS: Greater thoracic aortic diameters are associated with a higher risk of IA being larger than 7 mm and IA rupture. Exploring the concomitant growth tendency in IA and thoracic aorta provides a basis for future considerations regarding screening and risk management.


Assuntos
Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Fatores de Risco , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/complicações , Estudos Retrospectivos , Estudos de Coortes , Aorta Torácica/diagnóstico por imagem
18.
J Nutr Health Aging ; 28(3): 100167, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38307783

RESUMO

OBJECTIVES: Low muscle mass is related to cardiovascular risk factors. This study aimed to investigate whether relative low muscle mass is related to the diameter and tortuosity of the aorta. METHODS: We performed a cross-sectional study of 208 adults without known cardiovascular disease who underwent Computed Tomography (CT) enhanced scan between 2020 and 2021. Skeletal muscle index (SMI) was estimated. The morphology of the aorta was measured by diameter and tortuosity using CT. We assessed the relationship between SMI and diameter and tortuosity of the aorta using Spearman correlation analysis and univariate and multivariate-adjusted regression models. RESULTS: Of all -individuals, 124 (59.6%) were male. The average age was 60.13 ± 16.33 years old. SMI was inversely associated with the diameter and tortuosity of the aorta (p < 0.05). Specifically, in a multivariable-adjusted model adjusting for potential confounders, a one-unit increase in the SMI was associated with a -13.56mm(95% confidence intervals (CI): -18.16 to -8.96, p < 0.001), -7.93 mm (95% CI: -10.85 to -5.02, p < 0.001), -8.01 mm (95% CI: -11.30 to -4.73, p < 0.001), -5.16 mm (95% CI: -7.57 to -2.75, p < 0.001) and -2.73 mm (95% CI: -5.18 to -0.27, p = 0.031) increase in L1-L5 diameter respectively, a -0.89 (95% CI: -1.14 to -0.64, p < 0.001) increase in the aorta tortuosity, a -0.48 (95% CI: -0.59 to -0.36, p < 0.001) increase in the descending thoracic aorta tortuosity, and a -0.44 (95% CI: -0.52 to -0.35, p < 0.001) increase in the abdominal aorta tortuosity. CONCLUSIONS: Relative muscle mass was negatively associated with the diameter and tortuosity of the aorta, suggesting muscle mass maintenance may play a role in preventing aortic morphological changes.


Assuntos
Aorta Torácica , Neoplasias , Humanos , Masculino , Idoso , Feminino , Aorta Torácica/diagnóstico por imagem , Estudos Transversais , Aorta/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Músculo Esquelético/diagnóstico por imagem , Estudos Retrospectivos
19.
Surg Radiol Anat ; 46(4): 513-517, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38378882

RESUMO

PURPOSE: Here, we report a case of the right-sided aortic arch with isolation of the left innominate artery and hypoplasia of the left internal carotid artery. METHODS: A 42-year-old male patient underwent a whole-body computed tomography angiography (CTA) examination upon the clinical suspicion of vasculitis. RESULTS: CTA revealed a right-sided aortic arch with the isolation of the left innominate artery and hypoplasia of the left internal carotid artery. CONCLUSION: The right-sided aortic arch, with the isolation of the left innominate artery, is a scarce vascular variation that may occur with other cardiovascular anomalies such as ventricular septal defect. It can be asymptomatic or can present with symptoms of subclavian steal syndrome. Although its association with the agenesis of the left internal carotid artery has been reported, its association with the hypoplasia of the left internal carotid artery has not been reported previously to the best of our knowledge.


Assuntos
Aorta Torácica , Artéria Carótida Interna , Masculino , Humanos , Adulto , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/anormalidades , Artéria Carótida Interna/diagnóstico por imagem , Tronco Braquiocefálico/diagnóstico por imagem , Tronco Braquiocefálico/anormalidades , Tomografia Computadorizada por Raios X , Angiografia , Artéria Subclávia/anormalidades
20.
Khirurgiia (Mosk) ; (2): 90-96, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38344965

RESUMO

A right aortic arch is an anomaly of prenatal development characterized by location of aortic arch to the right from tracheal-esophageal complex. This variant of anatomy is usually asymptomatic and diagnosed accidentally. We performed open upper lobectomy for cancer of the upper lobe of the right lung in a patient with aortic arch dextraposition. Classical right-sided upper lobectomy in patients with right aortic arch is associated with certain difficulties. The most difficult objective is total excision of lymph nodes because trachea is hidden under aortic arch. A specific complication may be postoperative hoarseness associated with iatrogenic damage to the right recurrent laryngeal nerve.


Assuntos
Aorta Torácica , Neoplasias Pulmonares , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/anormalidades , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/patologia , Nervo Laríngeo Recorrente/patologia , Linfonodos/patologia , Tórax
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...